
Add to Cart
Stainless Steel speed 1m-1.75m/s Home Passenger Home Elevator
Space efficiency
The elevators with smallmachine room have improved its performance by reducing area of theirmachine rooms.With advantages in savingfloor areas and construction costs, theelevators are applicable to office buildings,hotels and supermarkets.
Optional
Machine room-less passenger elevator | ||||||||
Load(kg) | NO.of persons | speed(m/s) | door opening type | opening size (width X high mm) | net size (width X high mm) | Hoistway net size (mm) | ||
(width X high mm) | OH | PP | ||||||
630 | 8 | 1.0 | split door | 800 | 1300x1250 | 2100x1700 | 4500 | 1500 |
1.5 | 4600 | 1600 | ||||||
1.75 | 4700 | 1700 | ||||||
800 | 10 | 1.0 | 800 | 1400x1350 | 2200x1800 | 4500 | 1500 | |
1.5 | 4600 | 1600 | ||||||
1.75 | 4700 | 1700 | ||||||
1000 | 13 | 1.0 | 900 | 1600x1500 | 2400x2000 | 4500 | 1500 | |
1.5 | 4600 | 1600 | ||||||
1.75 | 4700 | 1700 | ||||||
1150 | 15 | 1.0 | 1000 | 1750x1500 | 2600x2000 | 4500 | 1500 | |
1.5 | 4600 | 1600 | ||||||
1.75 | 4700 | 1700 |
Small machine room passenger elevator | ||||||||||
Load(kg) | NO.of persons | speed(m/s) | door opening type | opening size (width X high mm) | net size (width X high mm) | Hoistway net size (mm) | machine room size(mm) | |||
(width X high mm) | OH | PP | width X high mm | MR.H | ||||||
630 | 8 | 1.0 | split door | 800 | 1300x1250 | 1900x1900 | 4400 | 1400 | 1900x1900 | 2300 |
1.5 | 4500 | 1500 | ||||||||
1.75 | 4700 | 1600 | ||||||||
800 | 10 | 1.0 | 800 | 1400x1350 | 2000x2000 | 4400 | 1400 | 2000x2000 | ||
1.5 | 4500 | 1500 | ||||||||
1.75 | 4600 | 1600 | ||||||||
1000 | 13 | 1.0 | 900 | 1600x1500 | 2200x2200 | 4400 | 1400 | 2200x2200 | ||
1.5 | 4500 | 1500 | ||||||||
1.75 | 4600 | 1600 | ||||||||
1150 | 15 | 1.0 | 1000 | 1750x1500 | 2300x2200 | 4400 | 1400 | 2300x2200 | ||
1.5 | 4500 | 1500 | ||||||||
1.75 | 4600 | 1600 |
Advanced drive system
Armed with advanced gearless permanent magnet synchronous traction machine(PMSM),our elevators are famous for their simple structure, high speed and stability. They can reach maximum speed up to the world leading level, therefore, basically suiting building with different floors.
The application of a series of intelligent technologies to Tenau villa not only brings you comfort but also health.
Safety function | |
Light curtains protection | In the door open and shut period,infrared light that covers thewhole door height is used to probe the door protection device of both the passengers and objects. |
Designated stop | If the lift can not open the door in the destination floor out of some reasonthe lift will close the door and travelto the next designated floor |
Overload holding stop | When the car is overload,the buzzer rings and stops the lift in the same floor |
Anti-stall timer protection | The lift stops operation due to slippery traction wire rope |
Start protection control | If the lift does not leave door zone within the designated time after it gets startedit will stop the operation |
Inspection operation | When the lift enters into inspection operation,the car travels at inching running |
Fault self-diagnosis | The controller canrecord 62 latest troubles so as to quickly remove the trouble and restore the lift operation. |
Repeated door closing | If the lift can not close the door dueto certain obstacle or interferencethe lifwill reopen orre-shut the door until sundries are eliminated. |
Up/down over-run and final limit protection | The device can effectiveby prevent froom the lift’s surging to the trouble and restore the lift operation. |
Down over-speed protection device | When the lift down 1.2time higher than the rated seed.this device will automatically cut off control mains.ston the motor running so as to stop lift down at over-speed. If the lift continues to down atover-speed,and the speed is 1.4time higher than rated speed,safety tongs act to force the lift stop in orderto ensure the safety. |
Upward over-speed protection device | When thelift up speed is 1.2times higher than rated speed,the device will automatically decelerate or brake the lift. |
Elevator cab prevents accidental movement | When the elevator is in theopen state,if there is accidental movement,the elevator cab can present the movement. |
The application of a series of intelligent technologies to Tenau villa not only brings you comfort but also health.
We offer a contactless button, push button, COP, LOP , hall lantern , segment ,dot matrix , LCD and TFT displays etc.
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail
Should you have any question ,pls do not hesitate to contact me.